New PStQuick polystyrene calibration standards contain pre-mixed quantities of polystyrene polymers in autosampler vials for calibration of GPC columns.
Product line Twelve (12) different kits containing polystyrene polymers of various molecular weights are available. Of the twelve kits, nine are individual kits, each containing 3 to 5 polystyrene polymers. The remaining three are composite kits containing 2 or 3 of the individual kits.
- PStQuick MP kits for calibrating TSK-GEL SuperMultiporeHZ columns
- PStQuick MP-N for TSKgel SuperMultiporeHZ-N
- PStQuick MP-M for TSKgel SuperMultiporeHZ-M
- PStQuick MP-H for TSKgel SuperMultiporeHZ-H
- PStQuick kits to calibrate other TSK-GEL GPC columns and GPC columns from other manufacturers
- PStQuick Kit-L for calibrating TSK-GEL mixed-bed N-type columns
- PStQuick Kit-M for calibrating TSK-GEL mixed-bed M-type columns
- PStQuick Kit-H for calibrating TSK-GEL mixed-bed H-type columns
- The concentrations of the polystyrene standards in the premixed vials vary from a low of 0.2mg/mL to a high of 1.6mg/mL.
- All PStQuick polystyrene calibration standards are available for reordering.
Contents of each kit For example, PStQuick Kit-M contains 20 vials each of grades C and D.
|
Polystyrene Calibration Mixtures |
TSKgel column |
A |
B |
C |
D |
E |
F |
G |
H |
Vials |
|
PStQuick MP-N |
SuperMultiporeHZ-N |
|
|
|
|
|
|
|

|
60 |
|
PStQuick MP-M |
SuperMultiporeHZ-M |
|
|
|
|
|
|

|
|
60 |
|
PStQuick MP-H |
SuperMultiporeHZ-H |
|

|
|
|
|
|
|
|
60 |
|
PStQuick Kit -H (High MW) |
Mixed Bed H-type |

|

|

|
|
|
|
|
|
60 (3 x 20) |
|
PStQuick Kit -M (Medium MW) |
Mixed Bed M-type |
|
|

|

|
|
|
|
|
40 (2 x 20) |
|
PStQuick Kit -L Low MW) |
Mixed Bed N-type |
|
|
|
|

|

|
|
|
40 (2 x 20) | |
Nominal MW of Kit Components For example, grade B contains polystyrene polymers of nominal molecular weights 5,480,000 - 706,000, 96,400 - 10,200 and 1,000. In the above Table it is shown that grade B is part of PStQuick MP-H and PStQuick Kit-H.
|
Polystyrene MW |
A |
B |
C |
D |
E |
F |
G |
H |
|
8,420,000 |

|
|
|
|
|
|
|
|
|
5,480,000 |
|

|
|
|
|
|
|
|
|
2,890,000 |
|
|

|
|
|
|
|
|
|
1,090,000 |

|
|
|

|
|
|
|
|
|
706,000 |
|

|
|
|
|
|

|
|
|
355,000 |
|
|

|
|

|
|
|
|
|
190,000 |
|
|
|
|
|
|
|
|
|
96,400 |
|
|
|
|
|
|
|
|
|
37,900 |
|
|
|
|
|
|
|
|
|
18,100 |
|
|
|
|
|
|
|
|
|
10,200 |
|
|
|
|
|
|
|
|
|
5,970 |
|
|
|
|
|
|
|
|
|
2,500 |
|
|
|
|
|
|
|
|
|
1,000 |
|
|
|
|
|
|
|
|
|
500 |
|
|
|
|
|
|
|
| |
Procedure - Simply add solvent, mix and inject onto the GPC column.
Ordering Information
|