Size Exclusion: Gel Permeation Chromatography
Proteins
Water-soluble Polymers
Polar Organic-soluble Polymers
Alpha
SuperAW
Organic-soluble Polymers


TSK-GEL Alpha and SuperAW columns were developed for the GPC analysis of polymers of intermediate polarity. As in the PW- and PWxl-type resins, the particles in TSK-GEL Alpha and SuperAW columns have a hydroxylated methacrylate polymer backbone, but they are crosslinked to a higher degree than PW- and PWxl-type columns to minimize swelling in polar organic solvents.

TSK-GEL Alpha and SuperAW particles are available in a wide variety of pore sizes.

- Use semi-micro TSK-GEL SuperAW columns

  • for high-throughput applications
  • to reduce solvent consumption
  • to reduce solvent disposal cost.

- Use TSK-GEL Alpha columns

  • when analysis time is not critical
  • when sample mass is not limited
  • to collect fractions
  • to obtain maximum number of plates (at the expense of analyis time).

Highlights:

  • Alpha and SuperAW columns
    • Particle sizes
      • SuperAW, 4-9μm particles
      • Alpha, 7-13μm particles
    • No or minimal swelling in a wide range of polar organic solvents: methanol, acetonitrile, DMSO, isopropanol, THF, and HFIP.
    • For high thoughput applications, TSK-GEL SuperAW columns provide equivalent resolution in 1/2 the time compared to TSK-GEL Alpha columns.

    • Accurate MW determination and normal retention of polystrene polymers in DMF solvent.

    • System peaks from salts in the eluent elute away from the oligomer of interest.

  • Applications: polymers that are soluble in methanol, acetonitrile, DMSO, isopropanol, or THF; can also be used for water-soluble polymers.


TSK-GEL SuperAW

TSK-GEL Alpha

TSK-GEL SuperAW column line consists of five columns and a mixed-bed column.

High efficiency TSK-GEL SuperAW columns are only available in 6.0mm ID x 15cm columns for High Throughput applications.

TSK-GEL Alpha column line consist of five columns and a mixed-bed column.

TSK-GEL Alpha columns are available in conventional 7.8mm ID x 30cm column formats.

 