Home  
  What's New  
  Products  
  Literature/Applications  
  Service/Support  
  About Us  
  Sitemap  
  Account  
  Shopping Cart  
  Search  
search
Tosoh Bioscience LLC: The Chemistry of Innovation
Gel Filtration Chromatography
SW
SWxl
SuperSW
TSKgel SuperSW2000
TSKgel SuperSW3000


TSK-GEL SuperSW columns, introduced in 1997, represent the third generation of high performance Gel Filtration columns that have become synonymous with analyzing protein molecular weights in the emerging field of biotechnology.

Particle Characteristics
TSK-GEL SuperSW-type columns contain smaller particles than SWxl-type columns; 4 micron versus 5 micron. In addition, the column internal diameter has been reduced from 7.8mm ID to 4.6mm ID to provide higher sensitivity in sample-limited cases and to cut down on solvent use.

HPLC System Requirements
It is important to employ an HPLC system that is optimized with regards to extra-column bandbroadening to take full advantage of the high column efficiency that can be obtained on SuperSW columns. See Separation Report 95 for recommendations.

Calibration Curves
The figure to the right shows the calibration curves for globular proteins for the two TSK-GEL SuperSW-type columns in comparison with those for the corresponding SWxl columns. The following table summarizes the molecular weight ranges for SuperSW2000 and SuperSW3000 columns for globular proteins, polyethylene oxides and dextrans that can, at least partially, access the pores. For comparative purposes, similar data is provided as well for TSK-GEL SW and SWxl-type columns.

Protein Calibration curves for
TSK-GEL SuperSW and SWxl



Properties and separation ranges for TSK-GEL SW-type packings (Molecular Weight in Da)

TSK-GEL packing

Particle
size (µm)

Pore
size (Å)

Globular
proteins

Dextrans

Polyethylene
glycols and oxides

SuperSW2000

4

125

5,000 - 1.5 x 10^5

1,000 - 3 x 10^4

500 - 15,000

G2000SWxl         
BioAssist G2SWxl

5

125

5,000 - 1.5 x 10^5

1,000 - 3 x 10^4

500 - 15,000

QC-PAK TSK200

5

125

5,000 - 1.5 x 10^5

1,000 - 3 x 10^4

500 - 15,000

G2000SW

10, 13

125

5,000 - 1 x 10^5

1,000 - 3 x 10^4

500 - 15,000

SuperSW3000

4

250

1 x 10^4 - 5 x 10^5

2,000 - 7 x 10^4

1,000 - 3.5 x 10^4

G3000SWxl
BioAssist G3SWxl

5

250

1 x 10^4 - 5 x 10^5

2,000 - 7 x 10^4

1,000 - 3.5 x 10^4

QC-PAK TSK300

5

250

1 x 10^4 - 5 x 10^5

2,000 - 7 x 10^4

1,000 - 3.5 x 10^4

G3000SW

10

250

1 x 10^4 - 5 x 10^5

2,000 - 7 x 10^4

1,000 - 3.5 x 10^4

           

G4000SWxl
BioAssist G4SWxl

8

450

2 x 10^4 - 7 x 10^6

4,000 - 5 x 10^5

2,000 - 2.5 x 10^5

G4000SW

13, 17

450

2 x 10^4 - 7 x 10^6

4,000 - 5 x 10^5

2,000 - 2.5 x 10^5

Data in the Table were generated using the following conditions:

Columns:

Two 4µm, 4.6mmIDx30cm TSK-GEL SuperSW columns in series; two 5µm, 7.8mmIDx30cm TSK-GEL SWxl columns in series; two 10µm, 7.5mmIDx60cm TSK-GEL SW columns in series

Elution:

Globular proteins: 0.3M NaCl in 0.1M (0.05M for SWxl columns) phosphate buffer, pH 7
Dextrans and polyethylene glycols and oxides (PEOs): distilled water


Return to Size Exclusion main page

Application Overview -- Gel Filtration Chromatography with TSK-GEL columns