Parts and Accessories
Molecular Weight Standards
Replacement Parts


Tosoh Bioscience offers a limited line of replacement parts for its columns and guard columns. With the introduction of TSK-GEL BioAssist series, the TSK-GEL column line consists of stainless steel, glass and PEEK columns.

The tubing, fittings and frits in the stainless steel TSK-GEL columns are manufactured from 316-grade stainless steel. The top and bottom end-fittings are engraved with the pore size of the frit. If the top frit plugs, the entire end-fitting can be removed and replaced. Order the appropriate replacement fitting according to the ID of the column. Stainless steel end-fittings will connect to the 10-32 PEEK or stainless steel nuts and ferrules on a standard HPLC system.

The end-fittings on the glass columns contain Pyrex® frits with a nominal 10μm pore size. The materials in the glass column fittings that come into contact with the sample and the mobile phase are chlorotrifluoroethylene and tetrafluoroethylene. The end-fittings will connect to 1/4-28 and also to M6 nuts and ferrules.

Tosoh Bioscience recommends that each column be protected by a guard column and filter. Guard columns are listed with corresponding columns in each section of this website. We recommend installing a pre-column filter in front of the (guard) column to avoid clogging the top frit, particularly when working with columns that contain smaller than 5μm particles. In addition, when suspecting debris from the breakdown of pump seals, we have found it beneficial to use a pre-injector membrane filter to prevent any particulates from reaching the injector and/or (guard) column.


Ordering information:
To place an order please click on the shopping cart next to the desired item, or contact Customer Service. Tosoh Bioscience LLC only accepts orders from customers in North and South America. For sales offices in other parts of the world, please click Locations.


Guard column products

P/N

Description

Details

19018

TSKgel Guard Cartridge Holder, Replaces P/N 14100

For 4.6mm ID guard columns

18206

TSKgel Super-guard Filter Holder

For Super-ODS, -Octyl and -Phenyl guard filters (PN 18207)

19308

TSKgel Cartridge Holder

For all 2mm ID guard columns

03432

TSKgel Guardgel Holder

For all 7.5mm ID stainless steel columns

08809

Guardgel Holder, Glass

For all 5mm and 8mm columns

16106

Guardgel Holder

For all 21.5mm ID stainless steel columns


Fittings

P/N

Description

Details

13998

Endfitting with fixed 1µm Frit

For TSK-GEL NPR columns

18254

Endfitting with fixed 1µm Frit

For TSK-GEL SuperH columns

18255

Endfitting with fixed 1µm Frit

For TSK-GEL Super Series RP & SuperHZ columns

07619

Endfitting with fixed 2µm Frit

For all 4.6mm ID, 5µm stainless steel columns

08092

Endfitting with fixed 2µm Frit

For all 6mm ID, 5µm stainless steel columns

08095

Endfitting with fixed 2µm Frit For all 7.5mm & 7.8mm ID, 5µm stainless steel columns

18544

Endfitting with fixed 2µm Frit

For TSK-GEL ODS-80Ts QA columns

18545

Endfitting with fixed 2µm Frit

For all 2mm ID stainless steel columns

19834

Endfitting with fixed 5µm Frit

For 4.6mm ID TSK-GEL BioAssist PEEK columns (except SW)

19838

Endfitting with fixed 5µm Frit

For TSK-GEL BioAssist PEEK SW columns

05748

Endfitting with fixed 10µm Frit

For all 7.5mm & 7.8mm ID, 10µm stainless steel columns

06191

Endfitting with fixed 10µm Frit

For all 21.5mm ID, > 10µm stainless steel columns

08600

Endfitting with fixed 10µm Pyrex Frit

For all 8mm ID glass columns

16104

Endfitting with fixed 10µm Pyrex Frit
For all 5mm ID glass columns

16105

Endfitting with fixed 10µm Pyrex Frit

For all 20mm ID glass columns

03400

Column End Plug, 1/4-28, 10 pk

For glass column fitting

02342

Male Nut Ferrule, 10-32, 1/16", stainless steel, 2 pk

 

16566

One-piece fingertight fitting, 10-32, 1/16", PEEK

 


Pre-injector filters

P/N

Description

Details

14594

Pre-injector membrane filter holder, stainless steel

For collecting debris generated by pump seals

03409

13mm Nylon membrane filters 0.45µm

For P/N 14594, pk 100


Pre-column filters

P/N

Description

03410

Pre-column filter with 0.5µm stainless steel frit

03411

Replacement 0.5µm stainless steel frits, pk 10

03430

Replacement 2µm stainless steel frits, pk 10, for P/N 03432


Tubing

P/N

Description

02353

Teflon Tubing, 1/16" x 0.01" x 150cm

02354

PEEK Tubing, 1/16" x 0.01" x 150cm

02359

Tefzel Tubing, 1/16" x 0.03" x 150cm

02374

Stainless Steel Tubing, 1/16" x 0.01" x 10cm, 5pk

02375

Stainless Steel Tubing, 1/16" x 0.02" x 10cm, 5pk

 

 


Return to HPLC Columns main page