The TSKgel Hxl column lines consists of eight columns with different pore sizes, TSKgel G1000Hxl through TSKgel G7000Hxl, and three columns with an extended linear range of the calibration curve, TSKgel GMHxl, TSKgel GMHxl-L and TSKgel MultiporeHxl-M. The calibration curves are shown to the right.
Main characteristics
- Ultra-low sample adsorption, i.e., the columns show true size exclusion behavior for most polymers
- Maximum operating temperature for TSKgel Hxl-type columns is 60°C for G1000Hxl, G2000Hxl, G2500Hxl and G3000Hxl, and 80°C for the remaining columns in the product line. See TSKgel Hhr-type columns for operating temperatures of 140°C.
- Limited solvent range. The columns are shipped in THF, which can be exchanged for a limited number of organic solvents (see Table below)
- TSKgel Hxl-type columns are conventional GPC columns with column dimensions of 7.8mm ID x 30cm. Most HPLC systems do not require optimization of extra-column bandbroadening effects when working with conventional GPC columns.
|
Calibration curves for TSKgel Hxl columns with polystyrene standards

|
| Solvent compatibility for TSKgel Hxl (and SuperHZ) columns The column shipping solvent limits the types of solvents that can be used with each column type.
|
Column type |
Shipping solvent* |
Can be replaced with |
|
Hxl1 and SuperHZ
|
|
benzene, chloroform, toluene, xylene, dichloromethane, dichloroethane |
|
|
carbon tetrachloride4, o-dichlorobenzene, dimethylformamide, dodecane, dimethyl sulfoxide, dioxane, ethylacetate, FC-113, hexane, pyridine, hexafluoroisopropanol/chloroform, methyl ethyl ketone, quinoline, cyclohexane |
|
|
m-cresol in chloroform, up to 10% hexafluoroisopropanol in chloroform |
|
|
dimethyl sulfoxide, dioxane, tetrahydrofuran, toluene |
|
|
1-chloronaphthalene, trichlorobenzene | |
- In case of TSKgel SuperHZ and Hxl, keep flow rate below <0.5mL/min during solvent change. Solvent can be changed one way/one time only.
- All TSKgel Hxl, Hhr, SuperHZ, SuperH and GMH analytical columns are shipped containing tetrahydrofuran (THF), except TSKgel GMH-HT columns, which contain o-dichlorobenzene.
- THF in TSKgel G1000Hxl columns cannot be replaced with dichloromethane or dichloroethane.
- Prolonged exposure to carbon tetrachloride can corrode the stainless steel parts of a column and an HPLC system.
* 100% methanol cannot be used with TSKgel H-type columns; use this solvent with TSKgel SW-type or Alpha-type columns. ** TSKgel H columns may be specially ordered with this shipping solvent.
Recommended solvents/Applications for TSKgel H-type columns
|
Recommended solvent |
Application |
|
THF |
polystyrene, epoxy resin, phenoxy resin, polycarbonate, polyisoprene, polyvinyl acetate, polyvinyl chloride, monoglycerides, fatty acids, poly(butadiene), polybutadiene, poly(methyl methacrylate), poly(styrene-butadiene), poly(styrene-acrylonitrile) |
|
N,N-Dimethylformamide (DMF) +/- 5mM LiBr |
polyvinyl chloride, polyvinyl fluoride, urea resins, polyurethane, polystyrene, polyester, polyimido ether, polyimido ester, polyphenol (aqueous solution), polyacrylonitrile |
|
o-Dichlorobenzene (ODCB) |
polyethylene, polypropylene |
|
Chloroform |
polycarboxylic ether, acrylic resin, epoxy resin, polystyrene |
|
m-Cresol/Chloroform |
nylon, polyester, polyamide, poly(ethylene terephthalate) |
|
Toluene |
polybutadiene, polysiloxane | |
Columns with linear calibration curves Two of the linear columns are so-called mixed-bed columns, in which particles with different pore sizes are blended to provide an extended linear calibration curve. The remaining column is a so-called multi-pore column, in which each particle contains a range of pore sizes that provide a linear calibration curve. The innovative multi-pore approach, pioneered by Tosoh, is a synthetic chemistry answer to the question of how to obtain a column with an extended linear calibration curve, while mixed-bed columns represent a mechanical way of obtaining a linear calibration curve. In general, Multipore columns have a smoother, more linear, calibration curve. See the product page for Multi-pore Technology for the principles behind mixed-bed and multi-pore columns.
GPC applications and recommended solvents
|
 |
|
Contact us:
Tech Service: 800-366-4875 (option #3)
Customer Service: 866-527-3587
info.tbl@tosoh.com | |
Return to HPLC Columns main page
Return to Size Exclusion main
EcoSEC GPC System main page
Separation Report -- Principles and Applications of High Performance GPC Columns:TSKgel Hxl Type Columns for Oligomer Analysis
|
| We
have updated our survey. Yes, we still love your feedback and it still takes
only 30 seconds.
|
| Please
click here .
|
|